Ultrasonic Nondestructive Testing on False Welding Joint of Spot Welding for 00Cr18Ni10N Stainless Steel

机译:00Cr18Ni10N不锈钢焊接光焊联合的超声波无损检测

获取原文

摘要

00Cr18Ni10N stainless steel spot-welded joints were inspected by ultrasound in transmission mode under the water. By comparing and studying ultrasonic transmission wave signals of the spot welded joint of existing nugget and the false welded joint which were received by digital oscilloscope, we find that there are differences in degree of attenuation between multi transmitted wave and primary transmitted wave of two kinds of joints. The degree of attenuation of multi transmitted wave of false welded joint is obviously less than that of the joint with nugget. Therefore, false welded joint can be judged and identified through the degree of attenuation of multi transmitted wave relative to primary transmitted wave, and the dissection results verify the feasibility of this test method.
机译:通过在水下的传动模式中通过超声检查00CR18NI10N不锈钢点焊接头。通过比较和研究现有扣核点焊接接头的超声波传输波信号和数字示波器接收的假焊接接头,我们发现多传输波和两种初级传输波之间的衰减程度存在差异关节。伪焊接接头的多透射波的衰减程度明显小于带有块的关节。因此,可以通过相对于初级透射波的多透射波的衰减程度来判断伪焊接接头,并且解剖结果验证了该测试方法的可行性。