首页> 外文会议>Asian Pacific Conference on Energy, Environment and Sustainable Development >Calculation Model of Peak Power Load Shifting of Electric Thermal Storage Air-conditioning System
【24h】

Calculation Model of Peak Power Load Shifting of Electric Thermal Storage Air-conditioning System

机译:电热蓄热空调系统峰值电力负荷移位计算模型

获取原文

摘要

The government and the power grid corporations pay close attention how to evaluate the peak power load shifting ability of electric thermal storage air-conditioning system scientifically and rationally. The evaluation method of existing standard was analyzed briefly, and a new operable evaluation model based on the field tests was put forward. Based on the above analysis, the peak power load shifting of four projects was analyzed. Example shows that the analysis model can provides the basis for calculating the power load shifting indicator of electric thermal storage air-conditioning project.
机译:政府和电网公司密切关注如何在科学和合理的科学和理性地评估电热储存空调系统的峰值电力负荷转化能力。简要分析了现有标准的评价方法,提出了一种基于现场测试的新可操作评价模型。基于上述分析,分析了四个项目的峰值功率负载转移。示例示出了分析模型可以为计算电热存储空调项目的功率负载转移指示器提供基础。