SRI International has prepared dynamically generated silica samples since 1980 for the National Institute of Occupational Safety and Health (NIOSH) and the American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing (PAT) programs. Aerosol-generated samples were developed in 1980 to more closely approximate real world samples and to improve intrabatch precision. Liquid-generated samples may provide tighter control limits, and this method has been reexamined as the generation procedure of choice. Sample preparation procedures have also been investigated to minimize analytical uncertainty and, hence, obtain a true evaluation of the sampling error. Samples were analyzed by SRI, NIOSH, and the Wisconsin Occupational Health Laboratory, using X-ray diffraction or Fourier transform infrared spectrometry (FTIR). Results were plotted and statistically evaluated, then compared to the existing PAT interlaboratory database.
机译:自1980年以来,斯里国际为国家职业安全和健康研究所(Niosh)和美国工业卫生协会(AIHA)能力分析测试(PAT)计划自1980年制备动态产生的二氧化硅样本。 1980年开发了气溶胶生成的样品,以更加紧密的真实世界样本,并提高侦录精度。液体产生的样品可以提供更紧密的控制限制,并且该方法已被重新审视为所选的生成程序。还研究了样品制备程序以最大限度地减少分析性不确定性,因此获得对采样误差的真实评估。使用X射线衍射或傅里叶变换红外光谱(FTIR),通过Sri,Niosh和Wisconsin职业健康实验室分析样品。结果绘制和统计学评估,然后与现有的PAT互联数据库相比。