首页> 外文会议>Americas Conference on Wind Engineering >Dynamic Properties of Stay Cables on the Bill Emerson Bridge
【24h】

Dynamic Properties of Stay Cables on the Bill Emerson Bridge

机译:贝尔艾默生桥上住宅的动态特性

获取原文

摘要

An experimental study was conducted to investigate dynamic response characteristics of the stay cables on the Bill Emerson Bridge in Missouri, USA. The natural frequencies and inherent damping ratios of selected stay cables are estimated based on the decaying free-vibration of the cables. Testing of selected stay cables was performed in three phases: before grouting, after grouting, and after the installation of one line of cross ties. After the installation of grout, cable frequencies decreased by 10-16%. Damping ratios for the grouted cables were found to be in the range of 0.12 to 0.45% of critical with Scruton numbers ranging generally from 2-4, below the target value of five for cables with aerodynamic surface treatments. When cross ties are added to the stay cables, the individual stays become a network of cables with both local and global modes and significantly higher frequencies. This results in cables that are more difficult to excite and a cable network with greater energy dissipation capability.
机译:实验研究旨在探讨在比尔·爱默生桥在美国密苏里州的斜拉索的动态响应特性。选择斜拉索的固有频率和阻尼固有比例基于电缆的衰减自由振动估计。选择斜拉索的测试分三个阶段进行:注浆,注浆,并安装后横撑一行的前后。安装灌浆后,电缆的频率下降了10-16%。阻尼灌浆电缆比率被发现是在0.12的范围内的临界0.45%与斯克拉顿数字通常范围从2-4,下面的5目标值用于与空气动力表面处理的电缆。当交叉关系添加到斜拉索,个人撑成为本地和全球模式和显著更高频率的电缆网络。这导致电缆是更难以激发和有线网络具有更大的能量耗散能力。