首页> 外文会议>International Heat Pipe Symposium >RESEARCH ON THE HEAT TRANSFER AND PERFORMANCE OPTIMIZATION OF LOOP HEAT PIPE FOR COOLING OF THE HIGH POWERED LED
【24h】

RESEARCH ON THE HEAT TRANSFER AND PERFORMANCE OPTIMIZATION OF LOOP HEAT PIPE FOR COOLING OF THE HIGH POWERED LED

机译:用于冷却高电源LED的环热管传热和性能优化研究

获取原文

摘要

While the issue of environmental problem becomes serious,the energy saving is requested from the illumination sector.And, as the attractive candidate for next generation illumination, the interest has been focused on the LED.However, the performance of LED decreasesdue to the high junction temperature, over 85 degrees, shorting the life time.Therefore the evaluation of heat transfer and performance optimization of loop heat pipe operation conditions for cooling high powered LED was made.As working fluid of loop heat pipe,HFC-134a and HFO-1234yf is applied.Optimal parameters were confirmed to be 70% for the amount of working fluid, the outer diameter of down comer tube and riser tube was Φ 10, the height of fin was 3mm, the pitch of fin was 5mm.As the results, the thermal resistance level was achieved 0.0419K/W and 0482K/W with using R-134a and HFO-1234yf, respectively.It is recognized that the possible use HFO-1234yfinstead of R-134a, as low GWP working fluid.
机译:虽然环境问题的问题变得严重,但从照明部门要求节能。作为下一代照明的有吸引力的候选者,兴趣已经集中在LED上。然而,LED的表现减少到高交界处温度超过85度,缩短寿命。因此,对冷却高功率LED的环热管操作条件进行了热传递和性能优化的评估。环路热管的工作流体,HFC-134a和hfo-1234yf是适用的。优化参数对于工作流体量确认为70%,下式的外径和提升管的外径为φ10,翅片的高度为3mm,鳍的间距为5mm.as,结果使用R-134A和HFO-1234YF分别达到热阻水平0.0419k / w和0482k / w.识别出可能使用R-134a的HFO-1234yfinStead,作为低GWP工作流体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号