首页> 外文会议>International conference on wearable micro and nano technologies for personalized health >Wearable System for Non-Invasive and Continuous Monitoring Central Aortic Pressure Curve and Augmentation Index
【24h】

Wearable System for Non-Invasive and Continuous Monitoring Central Aortic Pressure Curve and Augmentation Index

机译:用于无侵入性和连续监测中央主动脉压力曲线和增强指数的可穿戴系统

获取原文

摘要

The paper presents a non-invasive method and system for a long-term and continuous monitoring of the central aortic pressure (CAP) waveform and the augmentation index (AI). The CAP curve is estimated from the measured radial electrical bio-impedance (EBI) using spectral domain transfer functions (TF), which are established on the basis of data analysis during clinical experiments. Experiments were carried out on 3 volunteers by now. During the experiment, a 0.5 mg sublingual nitroglycerin tablet was administrated to each volunteer. Both, the reconstructed CAP curve and the AI have very good correlation with the results obtained by the SphygmoCor system. But, in opposite to the traditional tonometry based CAP curve and AI estimation methods, the proposed one is more convenient to use and allows continuous and long-term personalized monitoring of the CAP curve and of the AI.
机译:本文提出了一种非侵入性方法和系统,用于长期和连续监测中央主动脉压(帽)波形和增强指数(AI)。使用光谱域传递函数(TF)从测量的径向电气生物阻抗(EBI)估计盖曲线,这基于临床实验期间的数据分析建立。实验在3志愿者到现在进行。在实验期间,将0.5mg舌下硝酸甘油片剂给予每个志愿者。两者,重建的帽曲线和AI与由血压孔系统获得的结果具有非常好的相关性。但是,在与传统的基于Tononetry的帽曲线和AI估计方法相反,所提出的使用更方便,允许连续和长期的个性化监控帽曲线和AI。