This paper presents the design and preliminary experimental results of a concentrator-type photovoltaic module based on a free-form off-axis 800×XR-Kohler concentrator. The off-axis XR-Kohler concentrator is one of the advanced concentrators that perform high concentration with a large acceptance angle and excellent irradiance uniformity on a solar cell. As a result of on-sun characterization of the unglazed single-cell unit test rig, the temperature-corrected DC module efficiency was 32.2% at 25°C without an anti-reflective (AR) coating on the secondary optics, and the acceptance angle was more than ±1.0°. In addition, the non-corrected DC efficiency of an individual cell in a glazed 8-cell unit module mounted on a carousel tracking system was measured. The individual efficiency deviated in the range of 24.3-27.4%, owing to the mirror shape and alignment errors. The resultant series-connected efficiency was approximately 25% at direct normal irradiation (DNI) of 770 W/m~2.
机译:本文介绍了基于自由形式的离轴800×XR-Kohler浓缩器的聚光器型光伏模块的设计和初步实验结果。轴外XR-Kohler浓缩器是在太阳能电池上以大的验收角度和出色的辐照度均匀性执行高浓度的先进集中器之一。由于不氮化的单电池单元试验台的阳光特征,温度校正的直流模块效率在25°C下为32.2%而在二级光学器件上没有抗反射(AR)涂层,以及接受角度超过±1.0°。另外,测量安装在安装在转盘跟踪系统上的上釉8单元单元模块中的单个电池的未校正DC效率。由于镜子形状和对准误差,个体效率偏离在24.3-27.4%的范围内。直接正常辐射(DNI)为770W / m〜2的所得级联效率约为25%。