We report on a new type of whispering gallery mode (WGM) resonator made of out of low-loss polymer poly (methyl methacrylate) (PMMA). These optical cavities are fabricated using standard semiconductor processing methods in combination with a specific thermal reflow process. During this subsequent thermal treatment, surface tension leads to the goblet like geometry of the resonator and to an ultra smooth surface. The Q-factor of these goblet resonators is above 2.106 in the 1310 nm wavelength range. In order to demonstrate the applicability of the goblet resonators for bio sensing,Bovine Serum Albumin was detected by monitoring the shift of resonator modes due to protein adsorption.
机译:我们报告了一种新型耳语廊道模式(WGM)谐振器,由低损耗聚合物聚(甲基丙烯酸甲酯)(PMMA)制成。 使用标准半导体处理方法制造这些光学腔,与特定的热回流过程结合使用。 在此随后的热处理期间,表面张力导致谐振器的几何形状和超光滑表面。 这些老板谐振器的Q系数在1310nm波长范围内高于2.106。 为了证明Goblet谐振器的用于生物感测的适用性,通过监测由于蛋白质吸附引起的谐振器模式的偏移来检测牛血清白蛋白。