The loss due to dry flue gas is quite considerable in boilers. This paper presents a novel method of wireless and real time monitoring of this loss in an industrial boiler. The proposed system consists of measuring the percentage of CO_2 present in the flue gas, temperature of flue gas and the ambient temperature. All these signals from the sensor are suitably conditioned and then transmitted to the central station using ZigBee communication. ZigBee is a popular wireless protocol used in process industries. At the central station the loss due to dry flue gas is calculated and displayed. At the central station, an ARM7TDMI-S is used for data acquisition and for calculating the boiler loss. In this work, not only the parameters are measured, but also wirelessly communicated to the central station for finding the loss due to dry flue gas.
机译:锅炉中由于干烟气的损失是相当大的。本文提出了一种新颖的无线和实时监测工业锅炉的这种损失方法。所提出的系统包括测量烟道气中存在的CO_2的百分比,烟道气的温度和环境温度。来自传感器的所有这些信号都是适当调节的,然后使用ZigBee通信发送到中心站。 ZigBee是一种在过程行业中使用的流行无线协议。在中央站,计算并显示由于干烟气引起的损耗。在中央站,ARM7TDMI-S用于数据采集和计算锅炉损耗。在这项工作中,不仅测量了参数,而且还可以无线地传送到中央站,以寻找由于干烟道气引起的损耗。