In this paper, the authors discuss the influence of touch trigger probe system on CMM measurement performance based on measurement experiment results. A ring gage and a plug gage finished in high accuracy are employed as test pieces and the measurements performed under the conditions of combining different extension bar and approaching speed. Two main types of errors, periodic component and high frequency undulation, are verified. Introduction of the extension bar may significantly aggravate the accuracy and reliability, especially, associated with a comparatively large approaching speed. In addition, from the discussions on the generation mechanism of the periodic error and high-frequency undulation, some worthwhile references to engineering applications are also derived.
机译:本文基于测量实验结果,探讨了作者讨论了触发探头系统对CMM测量性能的影响。以高精度完成的环形计和塞子计是测试件和在组合不同延伸条和接近速度的条件下进行的测量。验证了两种主要类型的错误,周期性分量和高频波动。延伸栏的引入可以显着加剧精度和可靠性,特别是与相对较大的接近速度相关联。此外,从关于周期性误差和高频波动的发电机制的讨论,还导出了对工程应用的一些有价值的参考。