首页> 外文会议>International Conference on Applied Materials and Electronics Engineering >Estimation of Optimal Water Flow Rate of a Steel Roller Shutter with Water Film Cooling System
【24h】

Estimation of Optimal Water Flow Rate of a Steel Roller Shutter with Water Film Cooling System

机译:水膜冷却系统钢辊快门最优水流速的估计

获取原文

摘要

The hybrid inverse method to estimate the optimal water flow rate and surface temperature on the hot surface of the steel roller shutter with water film cooling system subjected to a fire environment is presented in this paper. The results show that the effect of the down-flowing water film flow rate on the present estimates cannot be negligible. The water-film system combined with the steel roller shutter can effectively improve the heat resistance and the temperature of the shutter slat surface can be controlled to around 100 °C. The optimal water flow rate is 110 L/min for a typical 3m x 3m steel roller shutter with water film cooling system.
机译:本文介绍了用经受火环境的水膜冷却系统估计钢辊挡板的热表面上的最佳水流速和表面温度的混合逆方法。结果表明,对目前估计数对下流水膜流量的影响不能忽略不计。与钢辊挡板结合的水膜系统可以有效地提高耐热性,并且挡板板的温度可以控制在约100℃。具有水膜冷却系统的典型3M X 3M钢滚轮挡板的最佳水流速率为110L / min。

著录项