首页> 外文会议>International Conference on Advances in Energy Engineering >Monitoring of heavy metal lead in environmentalwater sample by single-wall carbon nanotubes preconcentrationhyphenated with ICP-MS
【24h】

Monitoring of heavy metal lead in environmentalwater sample by single-wall carbon nanotubes preconcentrationhyphenated with ICP-MS

机译:用ICP-MS预浓缩的单壁碳纳米管在环境水样中监测重金属样品

获取原文

摘要

In order to evaluate the effects of heavy metals discharged in the use of fossil energy sources on the environment, a novel method using a microcolumn packed with single-walled carbon nanotubes (SWNTs) as a new adsorption material was developed for the preconcentration of trace Pb in environmental water sample prior to its monitoring by inductively coupled plasma mass spectrometry (ICP-MS). The adsorption behaviors of the analytes on SWNTs under dynamic conditions were 'studied systematically. The main factors influencing the preconcentration and 'monitoring of the analytes have been examined in detail. Under the optimum conditions, the detection limit for Pb was 5.4 pg mL~(-1); the relative standard deviation (RSD) was 3.9% (n= 9, c=1.0 ng mL~(-1)). This method was successfully applied for the monitoring of trace heavy metal Pb in real water Sample with the recoveries of 96.0-1 05%.
机译:为了评估在环境中使用化石能源的重金属对环境的影响,为使用单壁碳纳米管(SWNT)填充的微柱作为新吸附材料的新方法进行了痕量PB的预浓缩在通过电感耦合等离子体质谱(ICP-MS)监测之前的环境水样中。在系统上研究了动态条件下SWNT上的分析物的吸附行为。影响了影响前浓缩和“对分析物监测”的主要因素。在最佳条件下,Pb的检测限为5.4 pg ml〜(-1);相对标准偏差(RSD)为3.9%(n = 9,c = 1.0 ng ml〜(-1))。该方法成功地应用于实际水样中的痕量重金属PB的监测,其回收率为96.0-1 0.5%。