首页> 外文会议>International Conference on Management, Manufacturing and Materials Engineering >Modal and seismic analysis of ITER soft x-ray diagnostic camera
【24h】

Modal and seismic analysis of ITER soft x-ray diagnostic camera

机译:迭代软X射线诊断摄像机的模态和地震分析

获取原文
获取外文期刊封面目录资料

摘要

International thermonuclear experimental reactor (ITER) soft x-ray (SXR) diagnostic camera is an indispensible component used to measure signal intensity of SXR, which can reflect the internal properties of plasma. In this paper, the preliminary structural design and working principle of SXR camera is demonstrated, to investigate its seismic performance, modal analysis has been performed to obtain natural frequencies, effective mass and mode of vibration in first ten modes by means of ANSYS software. Then according to two parallel seismic analysis methods used in ITER, the calculations have been performed and the corresponding results have been illustrated respectively, the stress intensity and displacement are all within the allowable margin, which indicates that the design is reasonable and feasible. It will also provide beneficial reference for subsequent work.
机译:国际热核实验反应器(浸泡)软X射线(SXR)诊断摄像机是用于测量SXR信号强度的不可或缺的组件,可以反映等离子体的内部性质。在本文中,证明了SXR摄像机的初步结构设计和工作原理,研究了其地震性能,模态分析通过ANSYS软件进行了前十种模式的自然频率,有效质量和振动模式。然后根据迭代中使用的两个平行地震分析方法,已经进行了计算,并且分别示出了相应的结果,应力强度和位移全部在允许的边缘内,这表明设计是合理和可行的。它还将为后续工作提供有益的参考。