In order to enhance the anti-seismic performance of the frame structure and masonry structure with frame at bottom layer, combined shear wall consisting of frame and gridiron composite wall was proposed in this paper, and shear bearing capacity calculation method for the wall was researched. 1/2 scale frame-sparse gridiron composite walls were tested under reversed cyclic loading. Damage processes, load-bearing capacity and hysteretic curves characters of the walls were analyzed. Based on the experiments and reinforced concrete masonry walls data, the force features and shear resistance mechanism of the wall were analyzed, and general shear bearing capacity formula were put forward, and application methods under different conditions were given at the same time. Comparative analysis between calculation results and test results indicated that the formula was accurate enough, and can be referred to in the new construction and post-quake reconstruction of frame structure or masonry structure with frame at bottom layer.
机译:为了提高框架结构的抗震性能和在底层框架的框架结构,在本文中提出了由框架和栅格复合壁组成的组合剪切壁,研究了墙壁的剪切承载力计算方法。在反转的循环载荷下测试1/2刻度帧稀疏栅格复合墙。分析了墙壁的损坏过程,承载能力和滞后曲线特征。基于实验和钢筋混凝土砌体墙体数据,分析了壁的力特征和剪切电阻机理,提出了一般剪切承载力配方,同时给出了不同条件下的应用方法。计算结果与测试结果之间的比较分析表明,该公式足够精确,可以在底层框架结构或砌体结构的新建筑和后震结构中提及。