Research Of The Fins Thickness Based On 600MW Supercritical Boiler Water-wall Cross-Section Temperature Distribution

机译:基于600MW超临界锅炉水壁横截面温度分布的翅片厚度研究

获取原文

摘要

The finite element model of supercritical boiler water-wall has been established and the ANSYS10.0 was used to simulate cross-section temperature distribution. The simulation result shows that fin-point is the highest temperature on the whole water-wall cross-section. As the fins thickness changed, fin-point temperature has a optimal value; Basing on some 600MW supercritical boiler, it has an optimal value when the fins thickness ranged from 7mm to 9mm.
机译:已经建立了超临界锅炉水壁的有限元模型,并使用ANSYS10.0来模拟横截面温度分布。仿真结果表明,FIN点是整个水壁横截面上的最高温度。由于翅片厚度发生变化,翅片温度具有最佳值;基于约600MW超临界锅炉,当鳍片厚度范围为7mm至9mm时,它具有最佳值。