首页> 外文会议>International Conference on Civil, Architectural and Hydraulic Engineering >Effect of Panel Zone Strength on Ductility Capacity of Welded Beam-to-column Connections without Continuity Plates
【24h】

Effect of Panel Zone Strength on Ductility Capacity of Welded Beam-to-column Connections without Continuity Plates

机译:面板区强度对无连续板焊梁到柱连接延展性的影响

获取原文

摘要

Panel zone strength in welded moment-resisting-frame connections have a significant effect on the stress and strain distribution in the connection and consequently on connection performance. It is generally believed that panel zone yielding is a yield mechanism that contributes to ductility of moment frame connections, but connections with excessive panel zone deformation may have premature connection fracture and reduced ductility. The conclusion was drawn based on the theoretic analysis and tests on T-shaped connections with continuity plates. effect of panel zone strength on ductility capacity of welded beam-to-column connections without continuity plates were investigated through three-dimensional, nonlinear, finite-element analyses of connection subassemblies. results show that strong panel zone contributes to ductile performance of connections without continuity plates. The ductility of welded beam-to-column connection can be significantly improved by removing the continuity plates and providing with strong panel zone. The conclusion drawn from this paper is verified by experimental data available in the literature.
机译:焊接力矩抵抗框架连接中的面板区域强度对连接中的应力和应变分布具有显着影响,因此在连接性能上具有显着影响。通常认为,面板区域产生是一种屈服机制,其有助于力矩框架连接的延展性,但是与过多的面板区域变形的连接可能具有过早的连接断裂和降低的延展性。基于与连续板的T形连接的理论分析和测试来绘制了结论。通过连接子组件的三维,非线性有限元分析研究了面板区强度对没有连续板的焊接梁到柱连接延性容量的影响。结果表明,强面板区有助于与连续板的连接的延展性性能。通过去除连续板并提供强面板区域,可以显着改善焊接光束到柱连接的延展性。本文得出的结论是通过文献中可用的实验数据验证的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号