Cognitive decline represents the biggest limiting factor to independence in older adults. Speech analysis has emerged as an alternative to standard cognitive assessment tools. Temporal segmentation of speech is reported in many studies and typically employs a static threshold to define a pause. This study investigated the effect of using pause and utterance duration distribution data in differentiating between cognitively healthy and impaired older adults. Three sets of features were extracted from 187 speech recordings: temporal features using a static 250ms threshold; temporal features using a dynamic threshold; and pause and utterance duration distribution parameters. The ability of each of these sets to differentiate between cognitively healthy and cognitively impaired participants was investigated using a Linear Discriminant Analysis (LDA) classifier. Improvements of 0.22% (to 64.20%) in sensitivity, 6.33% (73.12%) in specificity, and 3.27% (68.66%) in overall accuracy were observed in the performance of the classifier using the pause and utterance duration distribution parameters when compared to the static temporal features. The use of the dynamic threshold had a negative impact on the classifier performance, with a decrease of 5.73% (to 58.25%) in sensitivity, 1.10% (65.69%) in specificity, and 3.42% (61.97%) in accuracy.
机译:认知下降是老年人独立的最大限制因素。言语分析已成为标准认知评估工具的替代品。在许多研究中报告了语音的时间分段,通常使用静态阈值来定义暂停。本研究调查了使用暂停和话语持续时间分布数据在分化认知健康和受损的老年人之间的影响。从187个语音记录中提取了三组特征:使用静态250ms阈值的时间特征;使用动态阈值的时间特征;并暂停和发声持续时间分布参数。使用线性判别分析(LDA)分类器研究了每种套装以区分认知健康和认知受损参与者的能力。在分类器的性能与暂停和发声持续时间分布参数的性能相比,在分类器的性能下,观察到敏感度为0.22%(64.20%)的特异性,6.33%(73.12%)和3.27%(68.66%)的总体精度。静态时间特征。使用动态阈值对分类器性能产生负面影响,敏感度的降低为5.73%(至58.25%),特异性为1.10%(65.69%),准确度为3.42%(61.97%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号