首页> 外文会议>International Conference on Energy, Environment and Sustainable Development >Simulation and Analysis on Operating Characteristics of Central Exhaust System in High-rise Residential
【24h】

Simulation and Analysis on Operating Characteristics of Central Exhaust System in High-rise Residential

机译:高层住宅中央排气系统运行特性的仿真分析

获取原文
获取外文期刊封面目录资料

摘要

Operating characteristics of variable cross section area of main duct in the main-branch central exhaust system was simulated based on various stories, operation rate and cross section area of main duct by FLUENT. The results show that there are certain obvious induced flow in the lower part of the system when the users in the upper floor work in the central exhaust system, and the internal pressure of main duct appears low- high-low trend in the system from the bottom to the top floor. The maximum pressure position is not in the bottom, but in the middle and lower floor of the system, where is the most disadvantageous floors of the exhaust system. It indicates that 400 mm × 500 mm is the necessary cross section area of main exhaust duct for 10 layers buildings, and 400 mm × 750 mm is the necessary one for 20 layers buildings.
机译:基于各种故事,操作速率和主要管道的横截面区域,模拟了主干道中央排气系统中主管的可变横截面区域的操作特性。结果表明,当中间排气系统的上层工作中的用户时,系统下部存在一定明显的诱导流量,并且主管的内部压力从系统中出现低低趋势底部到顶层。最大压力位置不在底部,但在系统的中间和下层,在哪里是排气系统中最不利的地板。它表示400毫米×500mm是10层建筑物的主排气管的必要横截面区域,400毫米×750mm是20层建筑物的必要一个。