摘要

Experiments using inspection system manufactured by GE, and a Ti-17 billet 350mm processing a reference block. Machining three sizes of FBHs were 1.2,2.0 and 3.2mm, with metal distances from 5 to 188 mm, divided into seven zones. Respectively by contact, conventional and multi-zone immersion to test the billet The focal depths in billet of multi-zone transducers were from 13 to 175 mm. The results showed that The signal-to-noise ratio of contact is Φ3.2-18dB, the operation is convenient and economy, but its sensitivity is relatively low. The S/N ratio of conventional immersion is Φ2.0-18dB, it has good reliability and high efficiency. The S/N ratio of multi-zone immersion is Φ1.2-14.5dB, and the efficiency is relatively low but it has high detection sensitivity with smaller defects. In order to ensure the quality of Ti-17 billet, should be prefer multi-zone immersion technique.
机译:使用GE制造的检查系统的实验,以及TI-17钢坯350mm处理参考块。加工三种尺寸的FBHS为1.2,2.0和3.2mm,金属距离为5至188毫米,分为七个区域。分别通过接触,常规和多区浸入测试坯料中央区换能器中的焦距为13至175mm。结果表明,接触的信噪比是φ3.2-18dB,操作方便经济,但其灵敏度相对较低。常规浸渍的S / N比为φ2.0-18dB,它具有良好的可靠性和高效率。多区浸没的S / N比为φ1.2-14.5dB,效率相对较低,但具有较小的检测灵敏度,具有较小的缺陷。为了确保TI-17坯料的质量,应更喜欢多区浸没技术。