首页> 外文会议>RILEM International Conference on Cracking in Pavements >Effect of Specimen Size on Fatigue Behavior of Asphalt Mixture in Laboratory Fatigue Tests
【24h】

Effect of Specimen Size on Fatigue Behavior of Asphalt Mixture in Laboratory Fatigue Tests

机译:试样大小对实验室疲劳试验中沥青混合料疲劳行为的影响

获取原文

摘要

Laboratory fatigue testing has been extensively used to estimate the resistance to fatigue cracking of asphalt mixtures. Researchers developed a number of test methods to estimate the fatigue behavior of an asphalt mixture. However, based on the classical fatigue analysis, fatigue lives obtained from different test devices are not comparable even when they are performed under the same mode of loading and environmental conditions for the same material. The differences in specimen geometry and load configuration will result in different stress-strain distributions inside the tested specimens leading to differences in local fatigue damage. In this paper, the size effect on the fatigue life is investigated. Uniaxial tension and compression (UT/C) fatigue tests were carried out using cylindrical specimens with three different sizes. Size effect on the fatigue test results are compared and analyzed using the partial healing (PH) material model, which describes the change of the complex modulus for a unit volume due to loading. The fatigue failure points determined by the classic approach, dissipated energy ratio and the PH model were compared. The results show that fatigue behavior of the specimens in the UT/C fatigue tests can be fitted excellently by the PH model, including estimation of the endurance limit. It is concluded that fatigue behavior from the UT/C fatigue test is not dramatically influenced by specimen size.
机译:实验室疲劳试验已被广泛地用于估计沥青混合物的疲劳破裂的抵抗力。研究人员开发了许多测试方法来估计沥青混合料的疲劳行为。然而,基于经典疲劳分析,即使在相同材料的加载和环境条件下执行时,从不同的测试装置获得的疲劳寿命也不相当。试样几何和负载配置的差异将导致测试标本内的不同应力 - 应变分布,导致局部疲劳损坏的差异。本文研究了对疲劳寿命的尺寸影响。使用具有三种不同尺寸的圆柱形样品进行单轴张力和压缩(UT / C)疲劳试验。使用部分愈合(pH)材料模型进行比较和分析对疲劳试验结果的尺寸效应,其描述了由于负载而导致的单位体积的复杂模量的变化。比较了通过经典方法,耗散能量比和pH模型确定的疲劳失效点。结果表明,UT / C疲劳试验中标本的疲劳行为可以通过pH模型出色,包括耐久极限的估计。得出结论,来自UT / C疲劳试验的疲劳行为没有受标本尺寸的显着影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号