Based on the previous experiments and theoretical analyses, finite element analyses (FEA) and parametric study on seismic behavior of Cover Plate Strengthen-Beam Flange Weaken Beam-to-Column (CPSBFW) connection are executed by using ABAQUS. Suggestions on design conceptions and details of the cover plate strengthen-beam flange weaken beam-to-column connection are presented in this paper, and that provide valuable reference for design of beam-to-column connections in steel structures.
机译:基于先前的实验和理论分析,通过使用ABAQU来执行有限元分析(FEA)和对盖板的地震行为的参数学研究,通过ABAQU来执行磁束到列(CPSBFW)连接。本文提出了关于盖板增强梁法兰的设计概念和细节的建议,并在本文中提出了光束到柱连接,为钢结构中的梁到柱连接设计提供了有价值的参考。