摘要

Based on a new type of sprayed liquid desiccant total heat recovery device, a liquid desiccant system combined refrigeration system with the independent humidity control (IHC) strategy is presented, in which the entire latent load and part of the sensible load are removed by liquid desiccant fresh unit combining heat pump (LFUH). The air-conditioning cooling load of a commercial building is simulated by DEST software. And the energy consumption is calculated respectively for conventional air conditioning system and IHC system. Compared with ordinary systems, IHC system can achieve savings of about 20% of the power consumption per annum. In addition, the average coefficient of chiller performance (COP) can increase about 13.5%. The result sows that IHC system has better application prospects.
机译:基于新型的喷涂液体干燥剂总热回收装置,提出了一种具有独立湿度控制(IHC)策略的液体干燥剂系统组合制冷系统,其中通过液体干燥剂除去了整个潜在的潜在载荷和部分明智的载荷新的单元结合热泵(LFUH)。商业建筑的空调冷却负荷由Dest软件模拟。对于传统空调系统和IHC系统,分别计算能耗。与普通系统相比,IHC系统可以达到每年功耗的约20%的节省。此外,冷却器性能的平均系数(COP)可以增加约13.5%。结果播种IHC系统具有更好的应用前景。