首页> 外文会议>International Conference on Civil Engineering, Architecture and Building Materials >Finite Element Analysis of Anti-seismic Performance of Flange Connection in Circular-pipe Tower Structures
【24h】

Finite Element Analysis of Anti-seismic Performance of Flange Connection in Circular-pipe Tower Structures

机译:圆管塔结构法兰连接抗震性能的有限元分析

获取原文

摘要

For tower structures located in high-intensity seismic zone, despite the importance of anti-seismic performance in flange connection, far less attention has been given to it. Based on finite element analysis results carried by ANSYS software, under pressure and moment, influence of stiffener height and axial compression stress ratio of steel pipe on the anti-seismic performance of flange connection was studied. The main results shows that lower axial compression stress ratio of steel pipe or higher stiffener height would improve the anti-seismic performance of flange connection. And closer flange connection from the end restraint would lead to better anti-seismic performance.
机译:对于位于高强度地震区的塔结构,尽管抗震性能在法兰连接中具有抗震性能的重要性,但它的关注远远不受影响。基于ANSYS软件携带的有限元分析结果,在压力和时刻,研究了钢管对钢管高度和轴向压力比对法兰连接抗震性能的影响。主要结果表明,钢管或更高的加强件高度的轴向压力比较低,将提高法兰连接的抗震性能。与最终约束的更近的法兰连接会导致更好的抗震性能。