It is available to obtain the flow-rate characteristics of pneumatic ejector with isothermal suction process. This study analyzes heat trans fer effects on dynamic suction process and discusses the parameters of isothermal vacuum tank. Experiments are carried out in temperature measurement with the stop method. The heat transfer ratio is obtained when the air is en trained from the acrylic ch amber under the vacuum condition. Decrement of air temperature inside the vacuum chamber is affected by ejector flow-rate characteristics, heat transfer material and heat transfer area. By enlarging heat transfer area with copper wires, the isothermal suction process can be realized and the flow-rate characteristics of ejector could be measured rapidly and conveniently.
机译:可以获得具有等温抽吸过程的气动喷射器的流量特性。本研究分析了热反线对动态抽吸过程的影响,并探讨了等温真空罐的参数。通过停止方法在温度测量中进行实验。当空气在真空条件下从丙烯酸CH琥珀训练时获得传热比。真空室内的空气温度的减小受喷射器流速特性,传热材料和传热面积的影响。通过用铜线扩大传热面积,可以实现等温抽吸过程,并且可以快速且方便地测量喷射器的流量特性。