In November 2008 APAS Specification 0214, 'Coatings for Concrete used in Sewage Works,' was updated to include a requirement for accelerated sewage resistance testing. This is achieved by partial immersion in raw sewage for a period of two years. At the end of this time no blistering, cracking or integrity loss is permitted. To date there are no coatings in Australia that have met this criteria. This paper reviews the outcomes of SA Water's Environmental Testing Program for accelerated corrosion testing particularly focussing on testing for wastewater applications. Anecdotal observations are made regarding the performance of coatings in a wastewater test chamber. In light of these observations, comment is made on coating selection and approvals for coatings in wastewater applications.
机译:2008年11月APAS规范0214,“污水工程中使用的混凝土涂层”,已更新,以包括加速污水抗性测试的要求。这是通过在原始污水中的部分浸入两年的时间来实现。在此时间结束时,允许没有起泡,开裂或完整性损失。迄今为止,澳大利亚没有涂层符合此标准。本文综述了SA水环境检测方案的结果,适用于加速腐蚀检测,特别关注对废水应用的测试。关于涂料在废水试验室中的涂层的性能进行了轶事观察。鉴于这些观察结果,在废水应用中的涂层选择和批准时进行评论。