A new method to infill the opening in the precast fabricated concrete shear wall was applied in China. In this paper, three geometrically identical precast fabricated shear wall specimens were constructed and tested under constant axial load and quasi-static cyclic lateral loading. The only difference among three specimens was the methods to infill the opening in the middle, the methods were respectively integration infill, masonry infill and without infill. The hysteretic curves, the skeleton curves, the failure process, the strain variation of reinforcement, the stiffness, the ductility and energy-dissipating capacity were obtained. The results and analysis showed that integration shear wall owns good seismic performance. Its bearing capacity, stiffness, energy-dissipating capacity are excellent while ductility is relatively poor. Masonry infilled wall and wall without infill also own good seismic performance.
机译:在中国采用一种新的填充制成的混凝土剪力墙开口的方法。 在本文中,在恒定轴向载荷和准静态循环横向负载下构建并测试了三种几何相同的预制剪力壁样本。 三种标本之间的唯一差异是填充中间的开口的方法,方法分别是集成填充,砌体填充,无填充。 滞后曲线,骨架曲线,故障过程,增强的应变变化,刚度,延展性和能量消散能力。 结果和分析表明,集成剪力墙拥有良好的地震性能。 它的承载力,刚度,能量消散能力优异,而延展性相对较差。 砌体indifed墙壁和墙壁没有填充也拥有良好的地震性能。