X-Ray Computed Tomography Studies of 3D Meso-Defect Volume Distribution Changes of Cement Paste Due to Carbonation

机译:X射线计算机断层扫描研究3D中型缺陷体积分布由于碳化而导致的水泥浆料

获取原文

摘要

X-ray computed tomography (XCT), a non-destructive test, was used to study three dimensional (3D) meso-defect volume distribution changes of cement paste due to carbonation. The 3D meso-defect volume from 0.02mm~3~5mm~3 before and after carbonation was analyzed through add-on modules of 3D defect analysis. The experimental results show that the meso-defect volume fraction before and after carbonation are 0.7685% and 2.44%, respectively. After carbonation, the smaller defect increased significantly than the bigger defect.
机译:X射线计算机断层扫描(XCT),一种非破坏性测试,用于研究由于碳酸化而研究水泥浆料的三维(3D)中缺陷体积分布变化。通过附加模块分析3D碳酸化模块之前和之后的3D中学缺陷体积在0.02mm〜3〜5mm〜3中的3D缺陷分析模块。实验结果表明,碳酸化之前和之后的中间缺陷体积分别为0.7685%和2.44%。碳酸化后,较小的缺陷显着增加到更大的缺陷。