The mechanical properties of fire-damaged reinforced concrete columns rehabilitated by carbon fiber-reinforced polymer (CFRP) rods were studied. This study aims at the effectiveness of CFRP through the contrast test. Nine specimens were tested, including three normal temperature control specimens, and six specimens heated under ISO834 standard fire. After the specimens were exposed to fire, three of them were rehabilitated by CFRP. All specimens were loaded monotonically to failure in the same way. The results showed that the failure of reinforced concrete columns rehabilitated by CFRP was due to losing stabilization, whereas the others were material broken. Furthermore, because of the fire, the load-bearing capacity of specimens was all declined sharply compared with these at normal temperature. From this research, comparing with these normal temperature control specimens, the load-bearing capacity of specimens exposed to fire firstly was ranged from 0.25 to 0.37 times. But the ratio of the loading capacity of specimens rehabilitated by CFRP and normal temperature control ones was ranged from 0.54 to 0.67.
机译:研究了碳纤维增强聚合物(CFRP)棒恢复的火灾损坏钢筋混凝土柱的机械性能。本研究旨在通过对比测试的CFRP的有效性。测试九个样本,包括三个常温控制样品,并在ISO834标准火灾下加热六个试样。在将标本暴露于火之后,其中三种通过CFRP恢复。所有标本都以相同的方式单调地装载以失效。结果表明,CFRP恢复的钢筋混凝土柱的失效是由于稳定稳定,而其他物质被破坏。此外,由于火灾,标本的承载能力均在常温下与这些急剧下降。从本研究开始,与这些常温控制样品相比,首先暴露于火灾的标本的承载能力为0.25至0.37倍。但CFRP和正常温度控制恢复的标本的负载能力的比例范围为0.54至0.67。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号