首页> 外文会议>International Symposium on Structural Integrity >Changes of the Fracture Toughness of ZG40Cr25Ni20 Furnace Tube after Service and the Corresponding Change of the Microstructure of the Fracture Surface
【24h】

Changes of the Fracture Toughness of ZG40Cr25Ni20 Furnace Tube after Service and the Corresponding Change of the Microstructure of the Fracture Surface

机译:Zg40Cr25Ni20炉管的裂缝韧性的变化与裂缝表面微观结构的相应变化

获取原文

摘要

According to the principle of fracture mechanics, the fracture toughness of the furnace tube after 30000 hours service and new furnace tube were tested with the MTS810 tester. The microstructure of fracture surface were analysed by the SEM. The results show that the fracture toughness of the furnace tube after service decreases greatly compared with that of the new furnace tube. The microstructure of fracture surface of the furnace tube changes significantly corresponding to the change of the fracture toughness.
机译:根据骨折力学原理,用MTS810测试仪测试30000小时服务和新炉管后炉管的断裂韧性。通过SEM分析骨折表面的微观结构。结果表明,与新炉管相比,炉管的断裂韧性降低了大大。炉管的断裂表面的微观结构显着变化对应于断裂韧性的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信