In order to test the applicability of the strength curves of rebound method and ultrasonic-rebound combined method of common concrete in estimating the strength of recycled concrete, basis on the C30 recycled concrete specimens with 70% of recycled coarse aggregate replacement are designed, then changing the replacement ratio of recycled coarse aggregate for experimental verification. The results show that It will lead to a large error if using the strength curves of common concrete to estimate the strength of recycled concrete, and the error grows with the growth of the replacement ratio of recycled coarse aggregate. So It is necessary to establish the special purpose strength curves of recycled concrete with the rate of recycled coarse aggregate. Finally, the strength curves of recycled concrete with recycled coarse aggregate are 30%,50%,70% and 100% are given in this test conditions in this paper.
机译:为了测试反弹法强度曲线的适用性和常见混凝土的超声回弹组合方法估算再生混凝土的强度,基于C30再循环混凝土试样,设计了70%回收粗骨料更换,然后改变实验验证再生粗骨料的替代比。结果表明,如果使用普通混凝土的强度曲线估计再生混凝土的强度,则会导致误差大,并且误差随着再生粗骨料的替代比的增长而增长。因此,有必要以再生粗骨料速率建立再生混凝土的特殊用途强度曲线。最后,在本文中,在该试验条件下给出了再循环粗骨料的再循环混凝土的强度曲线为30%,50%,70%和100%。