首页> 外文会议>International Conference on Civil Engineering,Architecture and Building Materials >Embedded Sensor for Detecting Corrosion of Reinforcement in Concrete
【24h】

Embedded Sensor for Detecting Corrosion of Reinforcement in Concrete

机译:用于检测混凝土腐蚀的嵌入式传感器

获取原文

摘要

Corrosion of reinforcement is a worldwide problem which causes premature degradations in reinforced concrete structures. Monitoring reinforcement corrosion in concrete can be achieved by embedding corrosion sensor within the concrete cover. In this research, capacitance-based embedded sensor was developed to monitor corrosion potential (E_(corr)) and corrosion rate (I_(corr)) parameters of reinforcement continuously. The sensors were tied to the reinforcement and embedded in concrete slab specimens followed by immersion into NaCl solution for 70 days. During this period, corrosion parameters were weekly recorded.
机译:加强腐蚀是一个全球问题,导致钢筋混凝土结构过早降解。通过将腐蚀传感器嵌入混凝土盖子内,可以实现混凝土中的混凝土中的加固腐蚀。在该研究中,开发了基于电容的嵌入式传感器,以监测腐蚀电位(E_(COR))和腐蚀速率(I_(COR))连续加固参数。传感器与加强件绑定并嵌入混凝土板样本中,然后浸入NaCl溶液中70天。在此期间,腐蚀参数每周记录。