Pinch technology and exergy analysis have been used independently or in Combination for the energy integration of process units. Both techniques were used in this work to study the energy performances of a new LPG production unit and compare them to those of an old one which is still in operation on the same site. Pinch analysis was used to estimate the consumption of hot and cold utility and investigate the possibility of its reduction. The obtained results showed that the pinch is of about 16 °C which is relatively close to the optimum. In addition, it was found that the actual configuration of heat exchangers does not show any significant anomalies leading to excessive utility consumption. Exergy analysis was used to estimate the extent of energy degradation in both units. It allowed us to pinpoint the areas of lowest efficiency and assess the progress achieved in energy conservation for this type of units.
机译:PINCH技术和Deerteny分析已独立使用或组合使用过程单元的能量集成。在这项工作中使用了这两种技术,以研究新的LPG生产单元的能量性能,并将它们与旧仍在同一站点运行的旧产品的能量表现。 PINCH分析用于估计冷热效用的消耗,并调查其减少的可能性。所得结果表明,夹切为约16℃,其相对接近最佳。此外,发现热交换器的实际配置不会显示出导致过度效用消耗的​​任何显着的异常。 Deerveny分析用于估计两个单元中的能量劣化程度。它使我们能够确定最低效率的领域,并评估这种类型的能量育中所取得的进展。