首页> 外文会议>Recycling of Electronic Waste Symposium >LEACHING TOXICITY OF PB AND BA CONTAINING IN CATHODE RAY TUBE GLASSES BY SEP-TCLP
【24h】

LEACHING TOXICITY OF PB AND BA CONTAINING IN CATHODE RAY TUBE GLASSES BY SEP-TCLP

机译:通过SEP-TCLP浸出含有阴极射线管玻璃的Pb和Ba的毒性

获取原文

摘要

In the present study, different types of cathode ray tube (CRT) glasses were examined by sequential extraction combined with TCLP to provide possible explanations for how Pb and Ba leach out from the waste CRT glasses and to give possible reasons for why they leach out. Sequential extraction results showed that Pb and Ba in the CRT glasses dominantly presented as the residual fraction. The exchangeable fractions of Pb and Ba were extremely low, less than 0.01 % of the total content, but they were higher than those required by the regulation limits, 5 and 100 mg/L for Pb and Ba, respectively. TCLP tests of the original CRT glasses and CRT glasses residues after each step of sequential extraction demonstrated that the extremely high leaching toxicity of CRT glasses mainly caused by its exchangeable and carbonate fractions of Pb and Ba.
机译:在本研究中,通过顺序提取来检查不同类型的阴极射线管(CRT)玻璃与TCLP联合,以提供PB和BA如何从废物CRT眼镜中浸出的可能解释,并为其浸出为何提供可能的原因。序贯提取结果表明,CRT眼镜中的Pb和Ba主要呈现为残余部分。 Pb和Ba的可交换部分非常低,小于总含量的0.01%,但它们分别高于Pb和Ba的调节限值5和100mg / L所需的部分。在顺序提取的每个步骤后,原始CRT眼镜和CRT眼镜残留的TCLP测试表明CRT眼镜的极高浸出毒性主要由其可更换和碳酸盐馏分的Pb和Ba引起的。