首页> 外文会议>International Conference on Material Science, Environmental Science and Computer Science >The Removal of Chromium (VI) by Synthesized CMC Stabilized Zero-valent Iron Materials
【24h】

The Removal of Chromium (VI) by Synthesized CMC Stabilized Zero-valent Iron Materials

机译:通过合成的CMC去除铬(VI)稳定的零价铁材料

获取原文
获取外文期刊封面目录资料

摘要

The removal of chromium(VI) by CMC stabilized nanoscale zero-valent iron (nZVI) and the effects of reaction temperature and CMC dosage on the removal efficiency of Cr(VI) were investigated through multi-group experiments on this paper. The experiental results revealed: (1) different dosages of CMC vary the degree of impact of the removal of Cr(VI), at the concentration of 0.5 g L~(-1), it has the highest removal efficiency. (2) The effect of temperature on the removal efficiency is negative. The higher the temperature is, the lower will be the removal efficiency. After 120 min of treatment, the removal efficiencies of Cr(VI) at various reaction temperatures from 0, 20, 30 to 40°C were recorded as 100%, 99.75%, 97.6%, 95.75%.
机译:通过在本文的多群实验研究了CMC稳定的纳米级零价铁(NZVI)和反应温度和CMC剂量对CR(VI)的去除效率的反应温度和CMC剂量的去除。实验结果显示:(1)不同剂量的CMC改变了Cr(VI)的去除的影响程度,浓度为0.5g L〜(-1),它具有最高的去除效率。 (2)温度对去除效率的影响是阴性的。温度越高,较低的效率是较低的。在处理120分钟后,将Cr(VI)在不同0,20,30至40℃的反应温度下的去除效率被记录为100%,99.75%,97.6%,95.75%。