首页> 外文会议>International Conference on Engineering Design and Optimization >Failure Analysis of Hydrogen Corrosion of the Lens Gasket
【24h】

Failure Analysis of Hydrogen Corrosion of the Lens Gasket

机译:镜片垫圈氢腐蚀的失效分析

获取原文

摘要

The 10MoWVNb steel lens gaskets are widely used for the flange linking of high pressure tube in the synthetic ammonia system in chemical fertilizer plant. The gasket worked in H_2-N_2-NH_3 environment at the temperature of 300°C. It often fails because of hydrogen corrosion. The microstructure and corrosion characteristic of the lens gasket were studied by optical microscope. The results showed that the hydrogen blister appeared preferentially at the interface of inclusions. The corrosion depth was 0.65 millimeter. There were little intergranular crack on inner surface.
机译:10MOWVNB钢透镜垫圈广泛用于化肥厂合成氨体系中的高压管的法兰连接。垫圈在300°C的温度下在H_2-N_2-NH_3环境中工作。它通常由于氢腐蚀而失败。通过光学显微镜研究了透镜垫圈的微观结构和腐蚀特性。结果表明,氢气在夹杂物的界面处优先出现。腐蚀深度为0.65毫米。内表面上的晶间裂缝很小。