Converter valve cooling system circuit consisted of internal cooling system circuit and external cooling system circuit. ±800kV DC power transmission converter valve water cooling system circuit was introduced in this paper. Certain cooling medium flow rate through the pressure of the main circulating pump promotion into the outdoor heat exchanger, through outdoor for thermal equipment will change the flow valve produces heat emissions into the air, cooling medium re-entering the thyristor tube converter valve cooling heating element, with a heat back to the main circulating pump inlet, to form a closed loop converter valve cooling system.
机译:转换阀冷却系统电路由内部冷却系统电路和外部冷却系统电路组成。本文介绍了±800kV直流电力传输转换阀水冷却系统电路。某些冷却介质流量通过主要循环泵升级到室外热交换器中的压力,通过室外的热设备将改变流量阀将热排放产生进入空气,冷却介质重新进入晶闸管转换阀冷却加热元件,热回到主循环泵入口,形成闭环转换器阀门冷却系统。