Cracks were found on 24" valve at steam header line. This header connects high pressure steam header from Module I to Module II, and the valve was installed in 1989. The cracks occurred at valve body and bonnet with total of seven cracks were observed. Due to risk of valve failure; fitness for service needs to be conducted to ensure valve service ability. Alternating current potential drop technique was used for measuring crack depth. The crack dimensions and material properties are used as input for finite element analysis modelling. Fatigue growth analysis and fracture mechanic analysis were conducted also to obtain of valve properties. The assessment shows that the valve is still in safe region based on API 579 Level 3 assessment but need to monitor the valve service temperature.
机译:在蒸汽集管线上的24“阀门发现了裂缝。该标头从模块I连接到模块II,阀门安装在1989年。阀体发生在阀体和阀罩中,观察到阀体总共发生摇动杆。由于阀门故障的风险;需要进行健身,以确保阀门服务能力。交流电流潜在液滴技术用于测量裂纹深度。裂缝尺寸和材料特性用作有限元分析建模的输入。疲劳生长进行分析和断裂技工分析,以获得阀门性能。评估表明,基于API 579 3级评估,阀门仍处于安全区域,但需要监测阀门服务温度。