首页> 外文会议>International Conference on Structural Analysis of Historic Constructions >Dynamic Identification and Monitoring of St. Torcato Church
【24h】

Dynamic Identification and Monitoring of St. Torcato Church

机译:圣托卡托教堂的动态识别与监测

获取原文

摘要

The paper is related to the San Torcato Church, in Guimaraes, Portugal. At the moment, the church has significant structural problems due to soil settlements. Cracks can be observed on the main and the lateral facades, the bell-towers are leaning, and the arches in the nave exhibit a failure mechanism with cracks and vertical deformations. Non-stabilized phenomena are present in the structure. To stabilize the damage, a structural intervention is planned to occur soon and the church is already monitored to follow the intervention. The paper clearly presents the problem with emphasis to the dynamic analysis carried out before the structural strengthening, namely: the experimental tests with output-only techniques for frequencies, damping and mode shapes estimation, FE model updating analysis and dynamic monitoring.
机译:本文与葡萄牙吉马拉斯的圣托茨卡托教堂有关。目前,教会由于土壤定居点而具有显着的结构性问题。在主要和横向外墙上可以观察到裂缝,钟塔倾斜,并且殿中的拱形具有裂缝和垂直变形的故障机理。结构中存在非稳定化现象。为了稳定损害,计划发生结构干预,并且已经监测教会遵循干预。本文清楚地提出了强调结构强化前进行的动态分析的问题,即:具有频率,阻尼和模式的输出技术的实验测试,估计,FE模型更新分析和动态监控。