首页> 外文会议>International Conference on Condition Monitoring and Machinery Failure Prevention Technologies >Analyzing resonance phenomenon in a blower for boiler utility and saved it from total breakdown -A case study
【24h】

Analyzing resonance phenomenon in a blower for boiler utility and saved it from total breakdown -A case study

机译:分析锅炉效用鼓风机中的共振现象,从总崩溃省去 - 案例研究

获取原文

摘要

Resonance is one of the most destructive phenomenon in rotating equipments that can cause irreversible problems on machines and plants and also considerable maintenance costs. In this case-study we are discussing about resonance problem in a blower for boiler utility section, which is discovered by analyzing FFT spectrum and Coast Down plot through the condition monitoring schedule. Then reinforcing the equipment's structure in order to shift the system's natural frequency to a suitable one to eliminate the problem. Reanalyzing the FFTs and Coast Down plot assure us that the problem is solved.
机译:共振是旋转设备中最具破坏性现象之一,可能会对机器和工厂产生不可逆转的问题以及相当大的维护成本。在这种情况下,研究我们正在讨论锅炉实用部的鼓风机中的共振问题,通过分析FFT光谱和通过条件监测时间表来发现的。然后加强设备的结构,以将系统的自然频率转移到合适的频率以消除问题。重新分析FFT和海岸向下策略确保您解决了问题。