首页> 外文会议>International Conference on Concentrating Photovoltaic Systems >Evaluation of Satellite Cirrus Data for Performance Models of CPV Modules
【24h】

Evaluation of Satellite Cirrus Data for Performance Models of CPV Modules

机译:CPV模块性能模型的卫星CIRRUS数据评估

获取原文

摘要

In this paper ground based measurements of CPV module efficiency measured in Freiburg, Germany, are correlated to ground based measurements of DNI/GNI ratios and to space-borne observations of cirrus clouds obtained from the SEVIRI radiometer aboard the European geostationary Meteosat Second Generation satellite. The efficiency of CPV modules is found to decrease when the ratio of DNI to GNI increases. Furthermore, relatively high DNI to GNI ratios are observed when no cirrus clouds are present. In contrast, no direct correlation of efficiency and cirrus cloud cover was found for cases when cirrus clouds are detected by the satellite. Within this paper we provide explanations for this. The satellite measurement of cirrus clouds can be definitely applied for a qualitative evaluation of results derived by CPV module performance models. Furthermore the information about cirrus clouds can be of interest for an assessment of operation locations for CPV power plants.
机译:在本文的基础上,德国弗赖堡中测量的CPV模块效率的测量与DNI / GNI比率的地面测量相关,以及从欧洲地球静止的MeteoSat第二代卫星的Seviri辐射计获得的卷云云的空间观测。当DNI与GNI的比率增加时,发现CPV模块的效率降低。此外,当没有存在卷云云时,观察到相对高的DNI对GNI比率。相比之下,没有发现卫星云云云的情况下发现效率和卷云覆盖的直接相关性。在本文中,我们为此提供了解释。螺旋云的卫星测量肯定可以应用于CPV模块性能模型的结果的定性评估。此外,有关CIRRUS云的信息对于评估CPV发电厂的操作位置可能感兴趣。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有