This paper constructed a fire simulation model for urban subway station with platform shield door system and carried out corresponding simulation analysis with the CFD software of FDS (Fire Dynamic Simulator). Different fire scenarios were set up according to the practical subway station environment. Some fire distribution properties, such as temperature, carbon monoxide concentration, visibility and the effect of platform shield doors to the ventilation speed at the entrance of the stair were analyzed. Hence, the relevant data could be more reliable and the simulation result is quite useful for fire safety design and management of urban subway station.
机译:本文构建了带平台屏蔽门系统的城市地铁站火灾仿真模型,对FDS(火力动力模拟器)的CFD软件进行了相应的仿真分析。根据实际地铁站环境建立了不同的火灾情景。分析了一些火灾分配性能,如温度,一氧化碳浓度,平台屏蔽门对楼梯入口处的通风速度的可视性和效果。因此,相关数据可能更加可靠,模拟结果对于城市地铁站的消防安全设计和管理非常有用。