This paper presents a field-weakening control method for V/Ɠ-controlled hoist drives. The method is based on the power limitation, which enables a load-dependent maximum speed without load measurement. In order to avoid the pull-out point of the hoist motor, the acceleration is halted if the motor input power exceeds a predefined limit. In addition, an integral (I) controller is used to reduce the steady-state error of the power limiter. The advantage of the proposed method is that a load sensor is not needed. Simulation and experimental results show that power limitation is suitable field-weakening method for V/f-controlled hoist drives.
机译:本文介绍了用于V /ɠ控制的提升机驱动器的现场弱化控制方法。该方法基于电源限制,这使得依赖于负载依赖性的最大速度而无需负载测量。为了避免提升电机的拉出点,如果电动机输入功率超过预定限制,则停止加速度。另外,积分(i)控制器用于减小功率限制器的稳态误差。所提出的方法的优点是不需要负载传感器。仿真和实验结果表明,功率限制是适用于V / F控制的提升机驱动的弱化方法。