首页> 外文会议>SAMPE Technical Conference and Exhibition >EVALUATION OF CUBIC SPECIMENS FOR COMPRESSION TESTING AT DIFFERENT STRAIN RATES
【24h】

EVALUATION OF CUBIC SPECIMENS FOR COMPRESSION TESTING AT DIFFERENT STRAIN RATES

机译:不同应变率压缩测试立方试样的评价

获取原文

摘要

Cubic test specimens fabricated using Newport NCT321/G150 carbon unitape prepreg have been tested under uniaxial compression. Three different methods based on - specimen surface strain measurement, strains based on actuator displacement, and relative displacement of loading platens, have been evaluated for determination of the material stiffness from the test. A finite element model was used to study the different factors affecting the strain measurement in a cubic specimen under compression loading. The experiments reveal that the use of surface strains results in least error in computation of modulus, which is further supported by the finite element analysis. The analysis also indicates that the stress distribution in specimens tend to be more uniform when the ratio of the platen to specimen modulus is about 10 or higher.
机译:使用Newport NCT321 / G150碳嵌合Prepreg制造的立方试样在单轴压缩下进行了测试。基于试样表面应变测量的三种不同的方法,基于致动器位移的菌株和装载压板的相对位移,得到测试中的材料刚度。使用有限元模型研究在压缩负荷下,影响影响立方标本中应变测量的不同因素。实验表明,表面菌株的使用导致计算模量的计算最小误差,这将通过有限元分析进一步支持。分析还表明,当压板与样本模量的比例为约10或更高时,试样的应力分布趋于更均匀。

著录项