首页> 外文会议>ICME International Conference on Complex Medical Engineering >Study of pH-sensitive magnetization transfer imaging in hyperacute brain infarction using a clinical 1.5 Tesla scanner
【24h】

Study of pH-sensitive magnetization transfer imaging in hyperacute brain infarction using a clinical 1.5 Tesla scanner

机译:使用临床1.5特斯拉扫描仪研究超急性脑梗死的pH敏感磁化转移成像

获取原文

摘要

When cerebral nervous tissue lacks of blood and oxygen, neurocyte is altered in metabolism, following with intracellular acid-base disturbance. Alteration of intracellular pH value can influence the magnetization transfer ratio (MTR). So pH-sensitive magnetization transfer imaging can reflect the alteration in metabolism. Using this technology to image ischemic brain may make an early detection and prognose ischemic penumbra. In our study, twelve male cats weighing 2.4 to 2.8 kg underwent permanent MCAO, and ischemic evolution was observed at a clinical 1.5-T scanner through clinical T1WI, T2WI, DWI and MT-imaging. MT-imaging readout was as spin-echo imaging with an offset frequency of 3.5 ppm. At last, compare the ability of clinical imaging and MT-imaging to detect cerebral infarct within the hyperacute stage. From the experiment results we could find that in 7 of 12 animals they displayed hypointensity in the occlusion side in the MT-imaging, when there were no any alterations in the clinical imaging yet. In other 5 of 12 animals, we could observe the intensity alterations in DWI and MT-imaging at the same time. In the experiment we found that MT-imaging was sensitive to detect infarct prior to current clinical sequences such as T1WI, T2WI and DWI. Meanwhile, analysing from cerebral blood flow (CBF), the CBF level for pH change approximates to the threshold of penumbra, so it indicates that boundary of lesion on MT-imaging may also approximate to the penumbra. We also come to a conclusion that CEST-imaging may be able to prognose ischemic penumbra.
机译:当脑神经组织缺乏血液和氧气时,神经细胞在代谢中改变,伴有细胞内酸碱干扰。细胞内pH值的改变可以影响磁化转移比(MTR)。因此pH敏感的磁化转移成像可以反映代谢的改变。使用这种技术到图像缺血性大脑可能会提前检测和预测缺血半影。在我们的研究中,在临床1.5-T扫描仪通过临床T1WI,T2WI,DWI和MT成像,在临床1.5-T扫描仪中观察到重量MCAO的12名雄性猫。 MT-Imaging ReadOut作为旋转回波成像,偏移频率为3.5ppm。最后,比较临床成像和MT-成像检测超缩短阶段内脑梗死的能力。从实验结果中,我们可以发现,当临床成像中没有任何改变时,它们在12只动物中显示出在MT成像中的闭塞侧的低度。在12只动物中的其他5个中,我们可以同时观察DWI和MT成像中的强度改变。在实验中,我们发现MT-成像在当前临床序列如T1WI,T2WI和DWI等临床序列之前检测梗塞敏感。同时,从脑血流(CBF)分析,CBF水平的pH变化近似于PENUMBRA的阈值,因此表明损伤对MT成像的边界也可能近似于PENUMBRA。我们还得出结论,CEST-成像可能能够预测缺血性PENUMBRA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号