Extracellular neural recording requires neural probes having more recording sites as well as limited volumes. With its mechanical characteristic and abundant process method, Silicon is a kind of material fit for producing neural probe. Silicon on insulator (SOI) is adopted in this paper to fabricate neural probes. The uniformity and manufacturability are improved. The fabricating process and testing results of a series of Multi channel micro neural probes were reported. The thickness of the probe is 15μm-30μm. The typical impedance characteristics of the record sites are around 2MΩ at 1k Hz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 μV. Spike recorded from individual site could exceed 700 μV. The average signal noise ratio was 7 or more.