首页> 外文会议>International Conference on Information and Multimedia Technology >Optimal Capacity of SVC to Compensate Flicker induced by Electric Arc Furnace
【24h】

Optimal Capacity of SVC to Compensate Flicker induced by Electric Arc Furnace

机译:SVC以补偿电弧炉诱导的闪烁的最佳容量

获取原文

摘要

Electric arc furnaces are one of the most severe sources to induce voltage flickers and hard to make an analysis model due to its chaotic characteristics. In this paper, a practical modeling strategy for electric arc furnaces is suggested. By using this model, the flicker phenomena induced by electric arc furnaces are simulated and analyzed to find out solutions for compensation. To compensate voltage variation and frequency fluctuation, we used SVC devices and suggested a novel scheme to identify the optimal capacity of SVCs by using Pst flicker index which is suggested on IEC standards.
机译:电弧炉是诱导电压闪烁的最严重的源之一,并且由于其混沌特性而难以进行分析模型。在本文中,建议了电弧炉的实际建模策略。通过使用该模型,模拟并分析电弧炉诱导的闪烁现象,以找出补偿解决方案。为了补偿电压变化和频率波动,我们使用了SVC设备,并建议使用PST闪烁指数来识别SVC的最佳容量,这在IEC标准上建议。