We describe design of two-polarization imaging array of 7 antenna-coupled TES-bolometers. The fabrication procedureinvolves both electron beam lithography and convenient optical lithography resulting in submicron definition of TESabsorber films (down to ~ 0.2 pm) integrated within planar submm-wave antenna. Concept of matching optics betweenthe long-focus optical telescope and lens-antenna TES bolometer array is described. Two-mirror short-focusing beamconcentrator in combination with image rotator provides signal coupling to immersion lenses of the array. Each TESbolometer is coupled via microstrip transmission line to only one polarization of two-polarization crossed double-slotlens-antenna. Design of cryogenic 0.3-K system accommodating the matching optics is presented. We describemultiplexing readout scheme, which combines tomography, rotational scanning of the image and frequency domaindivision methods that drastically reduce the amount of wiring and substantially increase the final image resolution,especially for low-dimension arrays.
机译:我们描述了7个天线耦合的TES-钻头仪的双极化成像阵列的设计。制造过程in电子束光刻和方便的光学光刻,导致TesaBsorber薄膜的亚微米定义(下降到〜0.2μm)集成在平面内部波天线内。描述了长焦光学望远镜和镜头 - 天线TES阵列的匹配光学的概念。双镜短聚焦光束CONTENTATOR与图像旋转器组合提供信号耦合到阵列的浸没透镜。每个陶瓷计通过微带传输线耦合到仅两极化交叉双槽天线的一个偏振。提供了适应匹配光学器件的低温0.3-k系统的设计。我们介绍了读出方案,其组合断层扫描,旋转扫描图像和频率域DomainDivision的方法,其大大减少了布线量并且基本上增加了最终图像分辨率,特别是对于低维数组。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号