首页> 外文会议>Conference on Chemical, Biological, Radiological, Nuclear, and Explosives Sensing >DMS-IMS2, GC-DMS, DMS-MS: DMS Hybrid Devices CombiningOrthogonal Principles of Separation for Challenging Applications
【24h】

DMS-IMS2, GC-DMS, DMS-MS: DMS Hybrid Devices CombiningOrthogonal Principles of Separation for Challenging Applications

机译:DMS-IMS2,GC-DMS,DMS-MS:DMS混合装置与具有挑战性应用的分离分离原理

获取原文

摘要

Sionex Differential Mobility Spectrometer (DMS) sensors can be used as standalone detectors in many applicationsbecause of their outstanding sensitivity and selectivity. However, in applications like field screening for toxic chemicalsand explosives, the number of possible interferents may be so high that additional separation becomes useful foridentification and for quantitative measurement. For these cases, we have developed several different hybridtechnologies. (1) DMS-IMS~2integrates bipolar differential mobility ion filtration with IMS drift time measurement inIMS drift tubes, one tube for each ion polarity. (2)The Sionex GC-DMS (microAnalyzer) combines a pre-concentrator, arapid and selective GC column that operates at high temperature in an air recirculation loop, and DMS ion filtration anddetection. (3) Sionex DMS-MS interfaces have been developed for several types of mass spectrometers, and dramaticallyimprove mass spec performance by filtering out unwanted species to reduce chemical noise and improve measurementaccuracy. The Sionex DMS-IMS2 first uses DMS to select positive and negative ions based on ion mobility variation with field(the a(E) function), then uses paired IMS sections to measure the low field mobility (K(0)). DMS separation depends onmany properties including the distribution of internal charges, rigidity, and clustering. The IMS drift times depend onmolecular size and onformation at low fields. A number of applications of this technology will be described, includingCWA's, TIC/IM, and explosives.The Sionex microAnalyzer GC-DMS system combines sophisticated preconcentration, thermal desorption, GCtemperature ramping, and DMS separation and detection in a compact, portable and field-deployable package. The list ofapplications for this technology is growing rapidly, currently including CWAs, BTEX, H25 and mercaptans, and others. Sionex DMS-MS interfaces are being used to make quantitative measurements of biomarkers, including breath markers,biofluid markers, and cancer-linked agents. DMS-MS improves the performance / cost tradeoff for the massspectrometer, greatly speeds analysis compared to LC-MS, and maintains measurement accuracy.
机译:SiONex差动迁移率光谱仪(DMS)传感器可以用作许多应用中的独立探测器,因为它们具有出色的灵敏度和选择性。然而,在诸如毒性化学品和爆炸物的场筛选等应用中,可能的干扰器的数量可能如此之高,即额外的分离变得有用,并且用于定量测量。对于这些情况,我们开发了几种不同的杂交技术。 (1)DMS-IMS〜2融合双极差分迁移率离子过滤,IMS漂移时间测量INIMS漂移管,每个离子极性的一个管。 (2)SiONEX GC-DMS(MicroAnalyzer)结合了在空气再循环回路中在高温下操作的预浓缩器,Arapid和选择性GC柱,以及DMS离子过滤andDetection。 (3)SiONEX DMS-MS接口已为几种类型的质谱仪开发,并通过过滤出不需要的物种来降低化学噪声并提高测量抑制来戏剧性地提高质量规范性能。 SiONEX DMS-IMS2首先使用DMS基于与场的离子迁移率变化选择正极和负离子(A(e)函数),然后使用配对的IMS部分来测量低场移动(k(0))。 DMS分离取决于关于内部电荷,刚性和聚类的分布。 IMS漂移时间依赖于低田地的尺寸和整体。将描述该技术的许多应用,包括CWA,TIC / IM和爆炸物。SiONEX MicroAnalyzer GC-DMS系统将复杂的预浓缩,热解吸,GCTEmperature斜坡和DMS分离和检测结合在紧凑,便携式和现场 - 可部署包。该技术的申请列表正在迅速增长,目前包括CWA,BTEX,H25和硫醇等。 SiONEX DMS-MS接口用于制备生物标志物的定量测量,包括呼吸标记,生物流体标志物和癌症连接剂。 DMS-MS提高了质谱仪的性能/成本折衷,与LC-MS相比,分析大大速度分析,并保持测量精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号