摘要

Valuable information from Monitoring and Diagnostics (M&D) equipment installed on aging power transformers help utility personnel operate and maintain critical infrastructure. M&D systems provide valuable on-line information from power transformers including gas in oil, internal hot spot temperature, insulation aging moisture content in winding insulation, bubbling temperature, and OLTC position tracking. This presentation reviews several methods of integrating M&D equipment to provide this information to SCADA and maintenance systems.
机译:在老化电力变压器上安装的监控和诊断(M&D)设备的有价值的信息有助于公用事业人员运营和维护关键基础架构。 M&D系统提供了来自电力变压器的有价值的在线信息,包括油,内部热点温度,绝缘性老化水分含量,绕组绝缘,起泡温度和OLTC位置跟踪。本演示审查了将M&D设备集成的多种方法,以向SCADA和维护系统提供此信息。