Vibration Sparking and Slot Discharge in Stator Windings

机译:定子绕组中的振动火花和槽放电

获取原文

摘要

In the late 1980s and again in the past few years, some turbine generator stator windings have apparently failed due to a mechanism variously referred to as spark erosion or vibration sparking. The mechanism can produce relatively intense sparking between the surface of the stator bar and the core. The intensity of the sparking is such that it may erode the groundwall insulation much more quickly than slot discharges. Unlike the normal loose coil/slot discharge failure process, spark erosion can happen anywhere in the winding, and not just in stator bars that are operating at high voltage. For this mechanism to occur, apparently (a) the partly conductive slot coating much be much more conductive than normal; and (b) the bar must be loose in the slot and vibrating under the magnetic forces.
机译:在20世纪80年代后期,在过去几年中,一些涡轮发电机定子绕组显然失效,由于各种机构称为火花腐蚀或振动火花。该机构可以在定子杆和芯的表面之间产生相对强烈的火花。火花的强度使得它可以比槽放电更快速地侵蚀地下墙绝缘。与正常的松动线圈/槽放电故障过程不同,火花腐蚀可能发生在绕组中的任何地方,而不仅仅是在高压下运行的定子条。对于这种机制发生,显然(a)部分导电槽涂层比正常更大的导电; (b)杆必须松动在槽中并在磁力下振动。